Medium CNG Systems

GL-24 Compressor System

GL-24-new

Click on the picture to see installations

Quick Specifications

ControlAutomatic PLC
Charge rate24 CFM -11.4 GGE/hr.
Gas usage1,440 CFH
Discharge pressure4,200 psig (PLC limited)
Number of stages4 stage reciprocating
Power9 kWh, 12.5 hp, 230V 3-phase
Inlet pressure2 to 7 min/max
DimensionsH 70“x W 32”x D 52”
Weight925 lbs
Performance DataGL-24 Performance Chart

Standard Features

Weatherproof Acoustic Enclosure with HMI Touchscreen User Interface

  • Graphical status display
  • Remote monitoring capability

Programmable Logic Controlled (PLC) Automatic Operation

  • Automatic start/stop
  • Temperature corrected fill (TCF)
  • Cascade priority control
  • GreenLine Vehicle Priority Fill (VPF) logic
  • Condensate auto drain system
  • Blowdown/Vapor recovery
  • Crankcase heater

Features (PLC monitored)

  • Discharge gas pressure/temperature
  • 1st, 2nd, 3rd Stage over pressure
  • Low/high inlet pressure
  • Oil temperature
  • Cycle lockout

Optional Features

  • Fast-fill buffer or cascade storage
  • Low pressure desiccant dryer
  • Multiple fill posts/dispensers

GL-70 Compressor System

GL-70-new

Click on the picture to see installations

Quick Specifications

ControlAutomatic PLC
Charge rate150 CFM -71 GGE/hr.
Gas usage9,000 CFH
Discharge pressure5,000 psig (300 Bar)
Number of stages5 stage reciprocating
Power70 kWh, 120 hp, 460V 3-phase
Inlet pressure10/30 min/max
DimensionsH 10' x W 8' x D 20' (enclosed)
Weight10,650/18,500 lbs (enclosed)

Standard Features

Weatherproof Enclosure

  • Wide service access doors
  • Partitioned control room with EXP barrier
  • Low/high pressure gas filtration
  • High capacity gas intercooler
  • Blow-down recovery/inlet buffer tank
  • Induction and exhaust vents
  • Internal explosion proof lighting

Programmable Logic Controlled (PLC)  Unattended Operation

  • Automatic start/stop with purge delay
  • Temperature corrected fill (TCF)
  • Priority bank control
  • Condensate auto drain system
  • Suction shutdown valve
  • Enclosure heater

Safety Features (PLC monitored)

  • Enclosure gas detection
  • Discharge gas pressure/temperature
  • Compressor temperature
  • Stage over pressure
  • Low/high inlet pressure
  • Low oil level
  • Cycle lockout

Optional Features

  • Fast-fill cascade storage
  • Low pressure dryer
  • Multiple fill posts/dispensers
  • Skid mount duplex configuration

HMI Touchscreen User Interface

  • Graphical status display